Perhaps you are in a bad condition and need help to solve all the troubles. Don’t worry, once you realize economic freedom, nothing can disturb your life. Our CFI-I study materials can help you out. Learning is the best way to make money. So you need to learn our CFI-I study materials carefully after you have paid for them. As long as you are determined to change your current condition, nothing can stop you. Once you get the CFI-I certificate, all things around you will turn positive changes. Never give up yourself. You have the right to own a bright future.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.
Topic 2
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.
Topic 3
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.
Topic 4
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.

>> CFI-I Passleader Review <<

New CFI-I Passleader Review Free PDF | High Pass-Rate Exam CFI-I Reference: Certified Fire Inspector I (CFI-1)

We respect the private information of our customers. If you buy the CFI-I exam materials from us, you personal information will be protected well. Once the payment finished, we will not look the information of you, and we also won’t send the junk mail to your email address. What’s more, we offer you free update for 365 days for CFI-I Exam Dumps, so that you can get the recent information for the exam. The latest version will be automatically sent to you by our system, if you have any other questions, just contact us.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q94-Q99):

NEW QUESTION # 94
How much clear space shall be maintained around the circumference of a fire hydrant (except as otherwise required or approved)?

  • A. 36 in. (914 mm)
  • B. 48 in. (1219 mm)
  • C. 24 in. (610 mm)
  • D. 60 in. (1524 mm)

Answer: A

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Clear Space Requirements for Fire Hydrants:
According to NFPA 1 (Fire Code), Section 18.5.7.1, a clear space of at least 36 inches (914 mm) must be maintained around the circumference of a fire hydrant.
Why 36 Inches is Required:
Maintaining 36 inches of clear space ensures that fire hydrants are:
Readily accessible for firefighters during emergencies.
Free from obstructions that may hinder operation or connection of hoses.
Other Options Explained:
Option A (24 in): Insufficient clearance; may obstruct hydrant accessibility.
Option C (48 in) and Option D (60 in): More than required; not mandated by NFPA 1.
Summary:
A 36-inch (914 mm) clear space must be maintained around the circumference of a fire hydrant to ensure accessibility and operability.


NEW QUESTION # 95
What is the color of a heat-sensing fire detector with a temperature classification of extra high?

  • A. Red
  • B. Blue
  • C. White
  • D. Green

Answer: A

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Heat Detector Color Codes:
According to NFPA 72 (National Fire Alarm and Signaling Code), heat-sensing fire detectors are color-coded based on their temperature classification:
White: Ordinary (135°F to 155°F).
Green: Intermediate (175°F to 225°F).
Blue: High (250°F to 300°F).
Red: Extra high (325°F to 375°F).
Why Red is the Correct answer:
Heat detectors classified as extra high operate at temperatures between 325°F and 375°F and are marked with a red color code.
Other Options Explained:
Option A (White): Ordinary temperature range.
Option B (Green): Intermediate temperature range.
Option C (Blue): High temperature range.
Summary:
The color of a heat-sensing fire detector with an extra high temperature classification is red.


NEW QUESTION # 96
On a routine inspection of an automobile repair garage, the inspector notes that there are open containers of paint in and around the garage. Which standard addresses the proper storage, handling, and use of the paint?

  • A. NFPA 58
  • B. NFPA 30
  • C. NFPA 10
  • D. NFPA 13

Answer: B

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Storage and Handling of Flammable Liquids:
NFPA 30 (Flammable and Combustible Liquids Code) specifically addresses the storage, handling, and use of flammable and combustible liquids, including paints, in commercial and industrial settings.
Why NFPA 30 Applies:
Paints often have volatile, flammable components that must be stored in compliant containers and cabinets to prevent fire hazards.
Other Options Explained:
Option A (NFPA 58): Focuses on liquefied petroleum gas (LP-Gas).
Option C (NFPA 13): Covers sprinkler systems.
Option D (NFPA 10): Addresses portable fire extinguishers.
Summary:
NFPA 30 governs the proper storage, handling, and use of paint and other flammable liquids.


NEW QUESTION # 97
How often should manual fire alarm boxes be visually inspected?

  • A. Semiannually
  • B. Annually
  • C. Monthly
  • D. Weekly

Answer: C

Explanation:
Visual inspections for fire alarm system components are outlined in NFPA 72, National Fire Alarm and Signaling Code, Table 14.3.1.
Monthly (B): Manual fire alarm boxes must be visually inspected monthly to ensure they are free from obstructions and visible to occupants.
Weekly (A): Weekly inspections are not required for manual pull stations.
Semiannually (C) and Annually (D): These intervals apply to other maintenance tasks, such as functional testing, not visual inspections.
Reference:
NFPA 72, Table 14.3.1: Inspection intervals for manual fire alarm boxes.


NEW QUESTION # 98
At what minimum pressure would automatic sprinkler piping be hydrostatically tested if the maximum system pressure is 175 psi (12 bar)?

  • A. 250 psi (17 bar)
  • B. 175 psi (12 bar)
  • C. 225 psi (15.5 bar)
  • D. 200 psi (13.8 bar)

Answer: D

Explanation:
According to NFPA 13, Standard for the Installation of Sprinkler Systems, all sprinkler piping must undergo a hydrostatic test to verify its strength and leak resistance.
Hydrostatic testing must be conducted at a pressure of 200 psi (13.8 bar) or 50 psi (3.4 bar) greater than the system's maximum working pressure, whichever is higher.
Since the maximum system pressure is 175 psi, the test pressure must be at least 200 psI .
175 psi (A) is the system pressure, not the test pressure.
225 psi (C) and 250 psi (D) exceed the required test pressure.
Reference:
NFPA 13, Section 25.2.1.1: Hydrostatic test requirements for sprinkler piping.


NEW QUESTION # 99
......

If you are an IT staff, do you want a promotion? Do you want to become a professional IT technical experts? Then please enroll in the NFPA CFI-I exam quickly. You know how important this certification to you. Do not worry about that you can't pass the exam, and do not doubt your ability. Join the NFPA CFI-I exam, then ValidBraindumps help you to solve the all the problem to prepare for the exam. It is a professional IT exam training site. With it, your exam problems will be solved. ValidBraindumps NFPA CFI-I Exam Training materials can help you to pass the exam easily. It has helped numerous candidates, and to ensure 100% success. Act quickly, to click the website of ValidBraindumps, come true you IT dream early.